KROHNE OPTIFLUX 5100

Electromagnetic flowmeter for demanding applications with aggressive and abrasive media

  • With chemically resistant ceramic tube for liquids with solid content (≤10%)
  • Up to +180°C / +356°F
  • Flange: DN15…300 / ½…12″, max. PN40 / ASME Cl 300; Sandwich: DN2.5…100 / ⅒…4″
  • 4…20 mA, pulse, frequency, status, HART®
SKU: KROHNE-00021 Categories: , ,

Next Day Delivery

Customer Support

Authentic Products

Description

The OPTIFLUX 5100 is an electromagnetic flowmeter (EMF) with a high-tech ceramic measuring tube for demanding process flows. It is particularly suited for applications in the chemical processing industry, the minerals and mining sector as well as in any other sectors of industry where highly aggressive or abrasive liquids occur. The EMF is the ideal solution for harsh process conditions with temperatures up to +180°C / +356°F, aggressive chemicals and solid content (up to 10%).

Thanks to the unique combination of material properties such as surface hardness and finish, mechanical strength, resistance to corrosion and temperature shock, the OPTIFLUX 5100 outclasses all traditionally lined EMFs. The flowmeter comes with flange or as flangeless and space-saving wafer version. Both versions are vacuum-resistant and comply with the Pressure Equipment Directive. The OPTIFLUX 5100 is approved for use in hazardous areas. A full on-site verification of the flowmeter without process interruption can be carried out using the OPTICHECK service tool.

Additional information
Brand